_FR-Basic D UV/NIR |
| |
Spectrometer 1 (UV/VIS) |
OceanOptics* HR4000 |
| Detector |
Toshiba TCD1304AP linear CCD array |
| Scanning range: |
200nm - 1100 nm |
| Number of Pixels |
3648 |
| Pixel Size |
8 μm x 200 μm |
| Pixel Well Depth |
~100.000 electrons |
| Optical Design |
f/4, Symmetrical crossed Czerny-Turner |
| Focal length |
101.6 mm input and output |
| Aperture |
standard 50 µm wide slit, other sizes are possible (5, 10, 25, 50, 100, 200) |
| Grating |
Grating #HC1, 200nm - 1100nm, best efficient 200nm - 1050nm |
| Detector Len |
L4, to increases light-collection efficiency |
| OFLV-200-1100 filter |
OFLV Variable Longpass Order-sorting Filter, to block second- and third-order light |
| UV enhanced window |
UV4 |
| Optical Fiber connector |
SMA 905 to 0.22 NA single-strand optical fiber |
| Optical resolution |
For 50μm slit ~1.8nm (FWHM), for different slit size 0.02nm - 8.4nm |
| Signal-to-noise ratio |
300:1 |
| A/D resolution |
14 bit |
| Dark noise |
12 RMS counts |
| Acquisition time |
3.8 milliseconds to 10 seconds |
| Corrected linearity |
>99.8% |
| |
|
|
Spectrometer 2 (NIR) |
OceanOptics* NIRQuest 512 |
| Detector |
Hamamatsu G9204-512 InGaAs linear array (cooled) |
| Scanning range: |
850nm - 1700 nm |
| Number of Pixels |
512 |
| Pixel Size |
25 µm x 500 µm |
| Pixel Well Depth |
~100.000 electrons |
| Optical Design |
f/4, Symmetrical crossed Czerny-Turner |
| Focal length |
42mm input |
| Aperture |
standard 50 µm wide slit, other sizes are possible (10, 25, 50, 100, 200) |
| Grating |
Grating NIR3, 150 l/mm, 900-1700 nm |
| Filter |
OF1-RG830 longpass NIR filter, to block second- and third-order light |
| Optical Fiber connector |
SMA 905 to 0.22 NA single-strand optical fiber |
| Optical resolution |
With 50μm slit ~3.6nm (FWHM), with different slit size 2.0nm - 12.3nm |
| Signal-to-noise ratio |
15000:1 @ 100msec integration, 13000:1 @ 1000msec |
| A/D resolution |
16 bit |
| Dark noise |
6 RMS counts @ 100msec integration, 12 RMS counts @ 1000msec |
| Acquisition time |
1 milliseconds to 120 seconds |
| Corrected linearity |
>99.8% |
| |
|
|
| |
Light Source |
| Lamp type |
Combined Deuterium - Tungsten Halogen Light Source (controlled indipendently) |
| Wavelength range |
200-410 nm (deuterium), 360-2000 nm (tungsten halogen) |
| Shutter |
Manual or Software control |
| Output |
3.8 watts (deuterium); 1.2 watts (tungsten halogen) |
| Lifetime |
~1500 hours (deuterium); 1500 hours (tungsten halogen) |
| Time to Stabilize |
~10min |
| |
|
|
| |
General characteristics |
| Sample size |
8mm - 200mm (irregular shape) |
| Computer requirements |
PC with Windows XP/Vista and a USB port available |
| Power requirements |
115VAC/230VAC (0.6A/0.3A) |
| Sort cut circuit |
Slow Blow Fuse 5A. |
| Dimensions (W x L x H) |
Standard Size: 440mm x 360mm x 180mm, Other sizes are possible to meet particular needs |
| Weight |
~16Kgr, depending on the configuration |
| |
|
|
|
| |
|
|